LioN-P, IO-Link I/O Hub
Product information
The LioN-P, IO-Link I/O Hub by Belden is engineered for robust industrial applications. Housed in a durable metal casing with a 60 mm width and an impressive IP69K protection rating, it can withstand harsh environments. The hub supports 16 digital input channels, profiting from its 8 x M12 A-coded I/O connections, ensuring secure and efficient connectivity. The device includes 1 x M12 A-coded IO-Link Class A connection with 5-poles, supporting streamlined PLC integrations. Preconfigured with PX0 settings, this 'Plug and Produce' capability allows effortless device replacement without manual reconfiguration.
Key benefits include enhanced durability due to its zinc die-cast nickel-plated housing, ensuring longevity even under extreme conditions. The wide operating temperature range from -20 °C to 70 °C makes it suitable for various industrial environments. The IP65, IP67, and IP69K ratings confirm its resistance to dust and water ingress, crucial for operational reliability.
Applications for the LioN-P IO-Link I/O Hub are extensive, primarily in automated and industrial settings where data integrity and system uptime are crucial. It is ideal for manufacturing plants, robotic systems, and any rigorous applications requiring reliable digital input transfer from sensors to control units.
Key benefits include enhanced durability due to its zinc die-cast nickel-plated housing, ensuring longevity even under extreme conditions. The wide operating temperature range from -20 °C to 70 °C makes it suitable for various industrial environments. The IP65, IP67, and IP69K ratings confirm its resistance to dust and water ingress, crucial for operational reliability.
Applications for the LioN-P IO-Link I/O Hub are extensive, primarily in automated and industrial settings where data integrity and system uptime are crucial. It is ideal for manufacturing plants, robotic systems, and any rigorous applications requiring reliable digital input transfer from sensors to control units.
Downloads
Specifications
Air Pressure (Operation): | 80 kPa … 106 kPa (up to 2000 m above sea level) |
---|---|
Air Pressure (Storage/Transport): | 80 kPa … 106 kPa (up to 2000 m above sea level) |
Ambient Temperature (Operation)*: | -20 °C to 70 °C |
Ambient Temperature (Storage/Transport): | -25 °C to 85 °C |
Ambient Temperature (operation), max: | 70.0 |
Ambient Temperature (operation), max (#1): | Error |
Ambient Temperature (operation), min.: | Error |
Ambient Temperature (operation), min. (#1): | -20.0 |
Ambient Temperature (storage/transport), max.: | Error |
Ambient Temperature (storage/transport), max. (#1): | 85.0 |
Ambient Temperature (storage/transport), min.: | -25.0 |
Ambient Temperature (storage/transport), min. (#1): | Error |
Bus connection / FE: | 500 V DC |
CE: | |
CSA: | Yes, via UL |
Channel Type (#1): | Type 1 acc. to IEC 61131-2 |
China RoHS-Compliant: | |
Configuration: | IODD, Process Data |
Connection (#2): | M12, 5-poles, A-coded |
Connection (#4): | M12, 5-poles, A-coded |
Connection Module Supply Voltage: | M12, 5-poles, A-coded |
Connection Sensor Supply Voltage: | via Module Supply Connection |
Contact Base Material (#1): | M12, A-coded, CuSn, Gold-plated |
Contact Bearer Material (#1): | PA |
Current Carrying Capacity of Connector (#1): | max. 4 A |
Current Carrying Capacity of Connector (#2): | max. 4 A |
Current Consumption (typ.): | 80 mA (at 24 V DC) |
Customer Specific Product: | |
Cycle Time / Update Rate (#1): | min. 1 ms |
Depth: | 6.2598 in |
Depth (#1): | 159 mm |
Diagnostic Indicator: | LED red |
Diagnostic Indicator (#1): | LED red |
Dimensions (W x H x D): | 60 mm x 31 mm x 159 mm |
EMC Directive: | 2014/30/EU |
EN 55022 Radio Interference Properties: | Class A |
EN 61000-4-2 Electrostatic Discharge (ESD): | Criterion B; 4 kV contact discharge, 8 kV air discharge |
EN 61000-4-3 Electromagnetic Field: | Criterion A; Field intensity: 10 V/m |
EN 61000-4-4 Fast Transients (Burst): | Criterion B, 2 kV |
EN 61000-4-5 Surge Voltage: | Criterion B; DC supply lines: ±0.5 kV/±0.5 kV (symmetrical/asymmetrical); For I/O ports with cables ≤ 30m |
EN 61000-4-6 Conducted immunity: | Criterion A; Test voltage 10 V |
Fastening Torque (Bus Connection): | M12: 0.5 Nm |
Fastening Torque (Fixing Screw): | M4: 1 Nm |
Fastening Torque (Ground Connection (FE)): | M4: 1 Nm |
Fastening Torque (I/O Connection): | M12: 0.5 Nm |
Fastening Torque (Power Connection): | M12: 0.5 Nm |
Flammabilty Class: | UL 94 (IEC 61010) |
Frame Type: | Type_2_V |
Height: | 31 mm |
Housing Color: | Grey Metallic |
Housing Material: | Metal, Zinc Die-cast |
Housing Plating: | Nickel, matt |
IO-Link: | |
IO-Link Class: | Class A |
Input Filter Time: | 0 to 3 ms, configurable |
Input Voltage Range "0" signal: | -0,3V DC ... 5 V DC |
Input Voltage Range "1" signal: | 15 V DC ... 30 V DC |
Input Wiring: | 2-, 3-wire |
Item Description: | 0960 IOL 381-001-PX0 |
Long Description (#1): | LioN-P, IO-Link I/O Hub, IO-Link, industrial metal housing, 60 mm, up to IP69K, 16 digital input channels, 8 x M12 A-coded I/O connection, 5-poles, 1x M12 A-coded IO-Link Class A connection, 5-poles, PX0 (Preconfigured Parameter Settings - Plug and |
Mean Time To Failure (MTTF): | 2111 years. acc. to Telcordia SR-332 (2011) 20°C |
Module Supply Voltage (Nominal): | 24 V DC (SELV/PELV) |
Module Supply Voltage (Range): | 18 V DC to 30 V DC |
Mounting: | 2 hole screw mounting. Use standard M4 x 25 / 30 screws with toothed lock washer (as per DIN 125) and self-locking nuts. |
Nominal Current: | typ. 5 mA |
Nominal Voltage (#2): | 24 V DC via US (module power supply) |
Number of Connections (#6): | 1 |
Number of Connections (#9): | 1 |
Number of Digital Input Channels: | max. 16, fixed |
Number of Ports (#1): | 8x, X1 to X8 |
O-Ring Material: | FKM |
Parameter Storage: | Supported |
Part Number (#1): | 934992052 |
Permissible Humidity (Operation): | 5 % ... 95 % (For UL applications max. 80 %) |
Permissible Humidity (Storage/Transport): | 5 % ... 95 % (For UL applications max. 80 %) |
Pollution Degree: | 3 acc. to EN 60664-1, VDE 0110-1 |
Potted: | |
Process Data Length: | 4 Bytes Input Data, 4 Bytes Output Data |
Product Family: | I/O Systems: Active - Standalone |
Product Sub Family: | LioN-P |
Protection Class: | III, IEC 61140, EN 61140, VDE 0140-1 |
Protection Degree / IP Rating**: | IP65, IP67, IP69K |
Protection Degree / IP Rating Note: | ** only if mounted and locked in combination with Hirschmann / Lumberg Automation connector. |
Protective Circuit (#1): | Electronicaly: Overload protection, short-circuit protection |
Protocol: | IO-Link |
Reverse Polarity Protection: | |
Reverse Polarity Protection (#1): | |
RoHS Compliant: | |
Sensor Current Supply: | max. 700 mA per module (Consider 1L+ limitation of connected IO-Link Master) |
Sensor Supply Voltage (Nominal): | 24 V DC (SELV/PELV) |
Sensor Supply Voltage (Range): | 18 V DC to 30 V DC |
Sensor Type: | PNP |
Shock Resistance: | 50 g / 11ms |
Specification (#4): | V1.1.2 |
Status Indicator (Inputs): | LED white or yellow per channel |
Status Indicator (Sensor Supply): | LED green |
Status Indicator (System Supply): | LED green |
System Power Supply Connection Note: | *do not connect / disconnect under voltage! |
Transmission Rate / COM Mode: | COM 3 (230.4 kbps) |
UL: | cULus Listed, UL 61010-1 |
UL-File: | E230848 |
US (System Supply Voltage) / FE: | 500 V DC |
Vibration Resistance: | 15 g / 5 -500 Hz |
Weight: | 390 g |
Width: | 60 mm |
Width (#1): | 2.3622 in |
uniek_nr: | aut934992052 |