The LioN-P, IO-Link I/O Hub is designed for robust industrial environments, featuring a 60 mm industrial metal housing and protection up to IP69K. It offers 10 digital input and 6 digital output channels, each with a capacity of 0.5 A and galvanic isolation. The hub includes 8 x M12 A-coded I/O connections (5-poles) and 1x M12 A-coded IO-Link Class B connection (5-poles). The hub supports PX0 (Preconfigured Parameter Settings - Plug and Produce device exchange), facilitating easy and quick device swapping. The unit is compatible with IO-Link protocol, and offers LED indicators for system supply, sensor, actuator supply, and diagnostics. Its compact design ensures reliable operation in a wide range of temperatures and environmental conditions.
Downloads
Specifications
Actuator Supply Voltage (Nominal): 24 V DC (SELV/PELV)
Actuator Supply Voltage (Range): 18 V DC to 30 V DC
Air Pressure (Operation): 80 kPa … 106 kPa (up to 2000 m above sea level)
Air Pressure (Storage/Transport): 80 kPa … 106 kPa (up to 2000 m above sea level)
Ambient Temperature (Operation)*: -20 °C to 70 °C
Ambient Temperature (Storage/Transport): -25 °C to 85 °C
Ambient Temperature (operation), max: 70.0
Ambient Temperature (operation), max (#1): Error
Ambient Temperature (operation), min.: Error
Ambient Temperature (operation), min. (#1): -20.0
Ambient Temperature (storage/transport), max.: Error
Ambient Temperature (storage/transport), max. (#1): 85.0
Ambient Temperature (storage/transport), min.: -25.0
Ambient Temperature (storage/transport), min. (#1): Error
Bus connection / FE: 500 V DC
CE:
CSA: Yes, via UL
Channel Type: p-switching
Channel Type (#1): Type 3 acc. to IEC 61131-2
China RoHS-Compliant:
Configuration: IODD, Process Data
Connection (#2): M12, 5-poles, A-coded
Connection (#3): M12, 5-poles, A-coded
Connection (#4): M12, 5-poles, A-coded
Connection Actuator Supply Voltage: via Module Supply Connection
Connection Module Supply Voltage: M12, 5-poles, A-coded
Connection Sensor Supply Voltage: via Module Supply Connection
Contact Base Material (#1): M12, A-coded, CuSn, Gold-plated
Contact Bearer Material (#1): PA
Current Carrying Capacity of Connector: max. 4 A
Current Carrying Capacity of Connector (#1): max. 4 A
Current Carrying Capacity of Connector (#2): max. 4 A
Current Consumption (typ.): 80 mA (at 24 V DC)
Customer Specific Product:
Cycle Time / Update Rate (#1): min. 1 ms
Depth: 6.2598 in
Depth (#1): 159 mm
Diagnostic Idicator: LED red per channel
Diagnostic Indicator: LED red
Diagnostic Indicator (#1): LED red
Diagnostic Indicator (#3): LED red
Diagnostic Indicator (#4): LED red per port
Dimensions (W x H x D): 60 mm x 31 mm x 159 mm
EMC Directive: 2014/30/EU
EN 55022 Radio Interference Properties: Class A
EN 61000-4-2 Electrostatic Discharge (ESD): Criterion B; 4 kV contact discharge, 8 kV air discharge
EN 61000-4-3 Electromagnetic Field: Criterion A; Field intensity: 10 V/m
EN 61000-4-4 Fast Transients (Burst): Criterion B, 2 kV
EN 61000-4-5 Surge Voltage: Criterion B; DC supply lines: ±0.5 kV/±0.5 kV (symmetrical/asymmetrical); For I/O ports with cables ≤ 30m
EN 61000-4-6 Conducted immunity: Criterion A; Test voltage 10 V
Fastening Torque (Bus Connection): M12: 0.5 Nm
Fastening Torque (Fixing Screw): M4: 1 Nm
Fastening Torque (Ground Connection (FE)): M4: 1 Nm
Fastening Torque (I/O Connection): M12: 0.5 Nm
Fastening Torque (Power Connection): M12: 0.5 Nm
Flammabilty Class: UL 94 (IEC 61010)
Frame Type: Type_2_V
Galvanically Isolated:
Height: 31 mm
Housing Color: Grey Metallic
Housing Material: Metal, Zinc Die-cast
Housing Plating: Nickel, matt
IO-Link:
IO-Link Class: Class B
Input Filter Time: 0 to 3 ms, configurable
Input Voltage Range "0" signal: -3 V DC …+5 V DC
Input Voltage Range "1" signal: 11 V DC … 30 V DC
Input Wiring: 2-, 3-, 4-wire
Item Description: 0960 IOL 385-001-PX0
Long Description (#1): LioN-P, IO-Link I/O Hub, IO-Link, industrial metal housing, 60 mm, up to IP69K, 10 digital input and 6 digital output channels (0.5 A) with galvanic isolation, 8 x M12 A-coded I/O connection, 5-poles, 1x M12 A-coded IO-Link Class B connection, 5-poles,
Mean Time To Failure (MTTF): 1781 years. acc. to Telcordia SR-332 (2011) 20°C
Module Supply Voltage (Nominal): 24 V DC (SELV/PELV)
Module Supply Voltage (Range): 18 V DC to 30 V DC
Mounting: 2 hole screw mounting. Use standard M4 x 25 / 30 screws with toothed lock washer (as per DIN 125) and self-locking nuts.
Nominal Current: typ. 5 mA
Nominal Voltage: 24 V DC via Uaux (supplied by 2L+ of IO-Link Master)
Nominal Voltage (#2): 24 V DC via US (module power supply)
Number of Connections (#6): 1
Number of Connections (#9): 1
Number of Digital Input Channels: max. 10, fixed
Number of Digital Output Channels: max. 6, fixed
Number of Ports: 3x, X6 to X8
Number of Ports (#1): 5x, X1 to X5
O-Ring Material: FKM
Output Current per Channel: max. 0,5 A
Output Current per Module: Consider 2L+ limitation of connected IO-Link Master
Output Wiring: 2-, 3-wire
Overload Behavior: Auto off and on switching / Manual restart
Parameter Storage: Supported
Part Number (#1): 935001052
Permissible Humidity (Operation): 5 % ... 95 % (For UL applications max. 80 %)
Permissible Humidity (Storage/Transport): 5 % ... 95 % (For UL applications max. 80 %)
Pollution Degree: 3 acc. to EN 60664-1, VDE 0110-1
Potted:
Process Data Length: 4 Bytes Input Data, 4 Bytes Output Data
Product Family: I/O Systems: Active - Standalone
Product Sub Family: LioN-P
Protection Class: III, IEC 61140, EN 61140, VDE 0140-1
Protection Degree / IP Rating**: IP65, IP67, IP69K
Protection Degree / IP Rating Note: ** only if mounted and locked in combination with Hirschmann / Lumberg Automation connector.
Protective Circuit: Electronicaly: Overload protection, short-circuit protection
Protective Circuit (#1): Electronicaly: Overload protection, short-circuit protection
Protocol: IO-Link
Reverse Polarity Protection:
Reverse Polarity Protection (#1):
Reverse Polarity Protection (#2):
RoHS Compliant:
Sensor Current Supply: max. 700 mA per module (Consider 1L+ limitation of connected IO-Link Master)
Sensor Supply Voltage (Nominal): 24 V DC (SELV/PELV)
Sensor Supply Voltage (Range): 18 V DC to 30 V DC
Sensor Type: PNP
Shock Resistance: 50 g / 11ms
Specification (#4): V1.1.2
Status Indicator (Actuator Supply): LED green
Status Indicator (Inputs): LED white or yellow per channel
Status Indicator (Outputs): LED white or yellow per channel
Status Indicator (Sensor Supply): LED green
Status Indicator (System Supply): LED green
System Power Supply Connection Note: *do not connect / disconnect under voltage!
Transmission Rate / COM Mode: COM 3 (230.4 kbps)
UL: cULus Listed, UL 61010-1
UL-File: E230848
US (System Supply Voltage) / FE: 500 V DC
Uaux / FE: 500 V DC
Vibration Resistance: 15 g / 5 -500 Hz
Weight: 390 g
Width: 60 mm
Width (#1): 2.3622 in