Product information
The LioN-X IO-Link Master is a versatile and innovative device that supports single protocol PROFINET and IoT protocol REST. Encased in a durable metal housing, it offers protection levels of IP67 and IP69K, making it ideal for use in demanding environments. This module features 4 IO-Link Master Ports Class A and 8 digital inputs, providing extensive connectivity options with 8 M12 A-coded I/O connections (5-poles), 2 M12 D-coded Ethernet connections (4-poles), and 2 M12 L-coded power supplies. The rugged construction is complemented by excellent electrical and environmental specifications such as operation in temperatures ranging from -20°C to +60°C and resistance to shock and vibration.
The benefits of the LioN-X IO-Link Master include high flexibility in system integration due to its multi-protocol support and robust design, ensuring reliable operation in industrial settings. Its capability to interface with various devices through IO-Link ports and its comprehensive diagnostic indicators ensure efficient troubleshooting and maintenance.
This IO-Link Master is particularly suitable for advanced automation systems, industrial control processes, and environments requiring high levels of protection against moisture and contaminants. Its fast cycle time and capacity to support substantial load make it an excellent choice for applications needing rapid data communication and robust performance.
The benefits of the LioN-X IO-Link Master include high flexibility in system integration due to its multi-protocol support and robust design, ensuring reliable operation in industrial settings. Its capability to interface with various devices through IO-Link ports and its comprehensive diagnostic indicators ensure efficient troubleshooting and maintenance.
This IO-Link Master is particularly suitable for advanced automation systems, industrial control processes, and environments requiring high levels of protection against moisture and contaminants. Its fast cycle time and capacity to support substantial load make it an excellent choice for applications needing rapid data communication and robust performance.
Downloads
Specifications
ACHILLES tested: | |
---|---|
Accessories to Order Separately: | Ethernet cable, mounting adapter, sensor/actuator cable, power cable |
Addressing (#2): | DCP |
Air Pressure (Operation): | 80 kPa … 106 kPa (up to 2000 m above sea level) |
Air Pressure (Storage/Transport): | 80 kPa … 106 kPa (up to 2000 m above sea level) |
Ambient Temperature (Operation)*: | -20 °C to 60 °C |
Ambient Temperature (Storage/Transport): | -20 °C to 60 °C |
Ambient Temperature (operation), max: | +60 °C |
Ambient Temperature (operation), max (#1): | 140 °F |
Ambient Temperature (operation), min.: | Error |
Ambient Temperature (operation), min. (#1): | -20 |
Ambient Temperature (storage/transport), max.: | 140 °F |
Ambient Temperature (storage/transport), max. (#1): | +60 °C |
Ambient Temperature (storage/transport), min.: | -20 |
Ambient Temperature (storage/transport), min. (#1): | Error |
Availability: | not yet available |
Bus connection / FE: | 2000 V DC |
CE: | |
CSA: | Yes, via UL |
Channel Type: | p-switching |
Channel Type (#1): | Type 1 acc. to IEC 61131-2 |
China RoHS-Compliant: | |
Conformance Class: | C (CC-C) |
Connection (#2): | M12, 5-poles, A-coded |
Connection (#3): | M12, 5-poles, A-coded |
Connection (#9): | M12, 5-poles, A-coded |
Connection (#10): | M12 4-poles, D-coded |
Connection Module Supply Voltage: | M12 Power, 5-poles, L-coded |
Connection Sensor Supply Voltage: | M12 Power, 5-poles, L-coded |
Contact Base Material (#1): | M12, D-coded, CuSn, Gold-plated | M12 Power, L-coded, CuNi, Gold-plated |
Contact Bearer Material (#1): | PA / TPU |
Customer Specific Product: | |
Cycle Time / Update Rate (#2): | min. 1 ms for all channels at 32 Byte IN / OUT |
Cycle Time / Update Rate (#3): | min. 1 ms |
Depth: | 7.874 in |
Depth (#1): | 200 mm |
Diagnostic Idicator: | LED red per port |
Diagnostic Indicator: | LED red |
Diagnostic Indicator (#1): | LED red |
Diagnostic Indicator (#2): | LED red per port |
Diagnostic Indicator (#4): | LED red per port |
Dimensions (W x H x D): | 60 mm x 31 mm x 200 mm |
EMC Directive: | 2014/30/EU |
EN 55032 Radio Interference Properties: | Class A |
EN 61000-4-2 Electrostatic Discharge (ESD): | Criterion B; 4 kV contact discharge, 8 kV air discharge |
EN 61000-4-3 Electromagnetic Field: | Criterion A; Field intensity: 10 V/m |
EN 61000-4-4 Fast Transients (Burst): | Criterion B, 2 kV |
EN 61000-4-5 Surge Voltage: | Criterion B; DC supply lines: ±0.5 kV/±0.5 kV (symmetrical/asymmetrical); For I/O ports with cables ≤ 30m |
EN 61000-4-6 Conducted immunity: | Criterion A; Test voltage 10 V |
Easy Device Replacement: | Supported, based on LLDP |
Fast Startup (FSU): | Supported, ≤ 4000 ms |
Fastening Torque (Bus Connection): | M12: 0.5 Nm |
Fastening Torque (Fixing Screw): | M4: 1 Nm |
Fastening Torque (Ground Connection (FE)): | M4: 1 Nm |
Fastening Torque (I/O Connection): | M12: 0.5 Nm |
Fastening Torque (Power Connection): | M12: 0.5 Nm |
Flammabilty Class: | UL 94 (IEC 61010) |
Galvanically Isolated: | |
Height: | 31 mm |
Housing Color: | Grey Metallic |
Housing Material: | Metal, zinc die-cast |
Housing Plating: | Nickel, matt |
IO-Link: | |
IO-Link Class A Ports: | 4x, X1 to X4 |
IO-Link Specification: | V1.1.3 |
Included in Delivery: | Attachable Labels: 15x, Sealing Caps: 5x M12 |
Input Filter Time: | configurable |
Input Voltage Range "0" signal: | -3 V DC …+5 V DC |
Input Voltage Range "1" signal: | 15 V DC ... 30 V DC |
Input Wiring: | 2-, 3-, 4-wire |
Item Description: | 0980 LSL 3010-121-0006-001 |
Long Description (#1): | LioN-X IO-Link Master, Single Protocol PROFINET, IoT Protocol REST, 4 IO-Link Master Ports Class A + 8 DI, metal housing IP67, IP69K, 60mm, 8 x M12 A-coded I/O connection 5-poles, 2 x M12 D-coded Ethernet connection 4-poles, 2 x M12 L-coded power supply |
Media Redundancy Protocol (MRP): | Supported, MRP client |
Module Supply Voltage (Nominal): | 24 V DC (SELV/PELV) |
Module Supply Voltage (Range): | 20V DC to 30 V DC |
Mounting: | 2 hole screw mounting. Use standard M4 x 25 / 30 screws with toothed lock washer (as per DIN 125) and self-locking nuts. |
Netload Class: | III |
Nominal Current 1L+ (Pin 1): | 2A |
Nominal Current C/Q (Pin 4): | 500mA |
Nominal Voltage: | 24 V DC via US |
Nominal Voltage (#1): | 24 V DC via US (system power supply) |
Nominal Voltage (#2): | 24 V DC via US (module power supply) |
Number of Connections (#5): | 2 |
Number of Connections (#6): | 2 |
Number of Digital Input Channels: | up to 16 |
Number of Digital Output Channels: | up to 4 |
Number of IO-Link Master Channels: | max. 4, configurable |
Number of Ports: | 8x, X1 to X4 |
Number of Ports (#1): | 8x, X1 to X8 |
O-Ring Material: | FKM |
Output Current per Channel: | max. 500mA |
Output Wiring: | 2-, 3-wire |
Overload Behavior: | Auto off and on switching / Manual restart |
PNO: | |
Parameter Storage (#1): | Supported |
Part Number (#1): | 935702001 |
Performance Class: | RT (switch supports IRT) |
Perm. Conductor Length to Device: | ≤ 20 m |
Permissible Humidity (Operation): | 5 % ... 95 % (For UL applications max. 80 %) |
Permissible Humidity (Storage/Transport): | 5 % ... 95 % (For UL applications max. 80 %) |
Pollution Degree: | 3 acc. to EN 60664-1, VDE 0110-1 |
Potted: | |
Product Family: | I/O Systems: Active - Standalone |
Product Sub Family: | LioN-Xlight |
Protection Class: | III, IEC 61140, EN 61140, VDE 0140-1 |
Protection Degree / IP Rating**: | IP65, IP67, IP69K |
Protection Degree / IP Rating Note: | *only if mounted and locked in combination with Hirschmann / Lumberg Automation connector. |
Protective Circuit: | Electronicaly: Overload protection, short-circuit protection |
Protective Circuit (#1): | Electronicaly: Overload protection, short-circuit protection |
Protocol (#4): | PROFINET |
REST API: | Cyclic data read/write, Diagnosis data, Event data |
Reverse Polarity Protection: | |
Reverse Polarity Protection (#1): | |
RoHS Compliant: | |
Sensor Current Supply: | max. 4A per port via Pin1L+ |
Sensor Supply Voltage (Nominal): | 24 V DC (SELV/PELV) |
Sensor Supply Voltage (Range): | 20V DC to 30 V DC |
Sensor Type: | PNP |
Shared Device: | Supported |
Shock Resistance: | 50 g / 11ms |
Specification: | V2.3 |
Status Indicator (IOL): | LED green per channel |
Status Indicator (Inputs): | LED white or yellow per channel |
Status Indicator (Outputs): | LED white or yellow per channel |
Status Indicator (Sensor Supply): | LED green |
Status Indicator (System Supply): | LED green |
Supported COM Modes: | 4.8 kBaud (COM 1), 38.4 kBaud (COM 2), 230.4 kBaud (COM 3) |
Supported Network Protocols (Other) (#2): | ARP, HTTP, Ping, SNMP V1, TCP/IP |
Syslog: | |
System Power Supply Connection Note: | *do not connect / disconnect under voltage! |
Topology Detection: | LLDP, SNMP V3 |
Transmission Method (#3): | 100 BASE-TX, with auto negotiation and auto crossing |
Transmission Rate (#5): | Fast Ethernet (10/100 Mbit/s), Full Duplex |
UL: | cULus Listed, UL 61010-1 |
UL / FE: | 500 V DC |
US (System Supply Voltage) / FE: | 500 V DC |
US / UL (Actuator Supply Voltage): | 500 V DC |
Uaux / FE: | 500 V DC |
Vibration Resistance: | 15 g / 5 -500 Hz |
Weight: | 500 g |
Width: | 60 mm |
Width (#1): | 2.3622 in |
uniek_nr: | 935702001 |