Product information
The LioN-X IO-Link Master is a versatile IO-Link master device, supporting the EtherNet/IP protocol as well as the IoT Protocol REST. Equipped with 8 IO-Link Master Ports Class A, this device is designed for high-performance industrial applications. It comes housed in a robust metal casing with an IP67 and IP69K rating, ensuring reliable operation in harsh environments. With its compact dimensions of 60 mm width, it is suitable for space-constrained settings. The LioN-X IO-Link Master features multiple M12 connections: 8 IO 5-poles for I/O connectivity, 2 D-coded for Ethernet, and 2 L-coded for power supply. The device is designed to support various network protocols and provides diagnostic and status indicators for easy monitoring.
The key benefits of the LioN-X IO-Link Master include its robust construction, high protection grade, and compatibility with multiple network protocols, enabling seamless integration into existing systems. Additionally, the device supports quick connect and device level ring, enhancing network reliability and reducing downtime. The comprehensive diagnostics and status indicators facilitate maintenance and troubleshooting.
The LioN-X IO-Link Master is ideal for various industrial applications requiring efficient communication and control, including automation systems, industrial machinery, and process control environments. Its plug-and-play design ensures easy installation and setup, making it a practical solution for enhancing system connectivity and performance.
The key benefits of the LioN-X IO-Link Master include its robust construction, high protection grade, and compatibility with multiple network protocols, enabling seamless integration into existing systems. Additionally, the device supports quick connect and device level ring, enhancing network reliability and reducing downtime. The comprehensive diagnostics and status indicators facilitate maintenance and troubleshooting.
The LioN-X IO-Link Master is ideal for various industrial applications requiring efficient communication and control, including automation systems, industrial machinery, and process control environments. Its plug-and-play design ensures easy installation and setup, making it a practical solution for enhancing system connectivity and performance.
Downloads
Specifications
ACHILLES tested: | |
---|---|
Accessories to Order Separately: | Ethernet cable, mounting adapter, sensor/actuator cable, power cable |
Addressing: | BootP, DHCP |
Air Pressure (Operation): | 80 kPa … 106 kPa (up to 2000 m above sea level) |
Air Pressure (Storage/Transport): | 80 kPa … 106 kPa (up to 2000 m above sea level) |
Ambient Temperature (Operation)*: | -20 °C to 60 °C |
Ambient Temperature (Storage/Transport): | -20 °C to 60 °C |
Ambient Temperature (operation), max: | +60 °C |
Ambient Temperature (operation), max (#1): | 140 °F |
Ambient Temperature (operation), min.: | Error |
Ambient Temperature (operation), min. (#1): | -20 |
Ambient Temperature (storage/transport), max.: | 140 °F |
Ambient Temperature (storage/transport), max. (#1): | +60 °C |
Ambient Temperature (storage/transport), min.: | -20 |
Ambient Temperature (storage/transport), min. (#1): | Error |
Bus connection / FE: | 2000 V DC |
CE: | |
CIP I/O Connection Limit: | 3 |
CIP Msg Connection Limit: | 6 |
CSA: | Yes, via UL |
Channel Type: | p-switching |
Channel Type (#1): | Type 1 acc. to IEC 61131-2 |
China RoHS-Compliant: | |
Connection (#2): | M12, 5-poles, A-coded |
Connection (#3): | M12, 5-poles, A-coded |
Connection (#9): | M12, 5-poles, A-coded |
Connection (#11): | M12, 4-poles, D-coded |
Connection Module Supply Voltage: | M12 Power, 5-poles, L-coded |
Connection Sensor Supply Voltage: | M12 Power, 5-poles, L-coded |
Connection Types: | Exclusive Owner, Input Only, Listen Only |
Contact Base Material (#1): | M12, D-coded, CuSn, Gold-plated | M12 Power, L-coded, CuNi, Gold-plated |
Contact Bearer Material (#1): | PA / TPU |
Customer Specific Product: | |
Cycle Time / Requested Packet Interval (RPI): | min. 1 ms |
Cycle Time / Update Rate (#2): | min. 1 ms for all channels at 32 Byte IN / OUT |
Depth: | 7.874 in |
Depth (#1): | 200 mm |
Device Level Ring (DLR): | Supported, beacon based |
Diagnostic Idicator: | LED red per port |
Diagnostic Indicator: | LED red |
Diagnostic Indicator (#1): | LED red |
Diagnostic Indicator (#2): | LED red per port |
Diagnostic Indicator (#4): | LED red per port |
Dimensions (W x H x D): | 60 mm x 31 mm x 200 mm |
EMC Directive: | 2014/30/EU |
EN 55032 Radio Interference Properties: | Class A |
EN 61000-4-2 Electrostatic Discharge (ESD): | Criterion B; 4 kV contact discharge, 8 kV air discharge |
EN 61000-4-3 Electromagnetic Field: | Criterion A; Field intensity: 10 V/m |
EN 61000-4-4 Fast Transients (Burst): | Criterion B, 2 kV |
EN 61000-4-5 Surge Voltage: | Criterion B; DC supply lines: ±0.5 kV/±0.5 kV (symmetrical/asymmetrical); For I/O ports with cables ≤ 30m |
EN 61000-4-6 Conducted immunity: | Criterion A; Test voltage 10 V |
Fastening Torque (Bus Connection): | M12: 0.5 Nm |
Fastening Torque (Fixing Screw): | M4: 1 Nm |
Fastening Torque (Ground Connection (FE)): | M4: 1 Nm |
Fastening Torque (I/O Connection): | M12: 0.5 Nm |
Fastening Torque (Power Connection): | M12: 0.5 Nm |
Flammabilty Class: | UL 94 (IEC 61010) |
Galvanically Isolated: | |
Height: | 31 mm |
Housing Color: | Grey Metallic |
Housing Material: | Metal, zinc die-cast |
Housing Plating: | Nickel, matt |
IO-Link: | |
IO-Link Class A Ports: | 8x, X1 to X8 |
IO-Link Specification: | V1.1.3 |
Included in Delivery: | Attachable Labels: 15x, Sealing Caps: 5x M12 |
Input Filter Time: | configurable |
Input Voltage Range "0" signal: | -3 V DC …+5 V DC |
Input Voltage Range "1" signal: | 15 V DC ... 30 V DC |
Input Wiring: | 2-, 3-, 4-wire |
Item Description: | 0980 LSL 3111-121-0006-002 |
Long Description (#1): | LioN-X IO-Link Master, Single Protocol EtherNet/IP, IoT Protocol REST, 8 IO-Link Master Ports Class A, metal housing IP67, IP69K, 60mm, 8 x M12 A-coded I/O connection 5-poles, 2 x M12 D-coded Ethernet connection 4-poles, 2 x M12 L-coded power supply |
Module Supply Voltage (Nominal): | 24 V DC (SELV/PELV) |
Module Supply Voltage (Range): | 20V DC to 30 V DC |
Mounting: | 2 hole screw mounting. Use standard M4 x 25 / 30 screws with toothed lock washer (as per DIN 125) and self-locking nuts. |
Nominal Current 1L+ (Pin 1): | 2A |
Nominal Current C/Q (Pin 4): | 500mA |
Nominal Voltage: | 24 V DC via US |
Nominal Voltage (#1): | 24 V DC via US (system power supply) |
Nominal Voltage (#2): | 24 V DC via US (module power supply) |
Number of Connections (#3): | 2 |
Number of Connections (#6): | 2 |
Number of Digital Input Channels: | up to 16 |
Number of Digital Output Channels: | up to 8 |
Number of IO-Link Master Channels: | max. 8, configurable |
Number of Ports: | 8x, X1 to X8 |
Number of Ports (#1): | 8x, X1 to X8 |
O-Ring Material: | FKM |
ODVA: | |
Output Current per Channel: | max. 500mA |
Output Wiring: | 2-, 3-wire |
Overload Behavior: | Auto off and on switching / Manual restart |
Parameter Storage (#1): | Supported |
Part Number (#1): | 935701002 |
Perm. Conductor Length to Device: | ≤ 20 m |
Permissible Humidity (Operation): | 5 % ... 95 % (For UL applications max. 80 %) |
Permissible Humidity (Storage/Transport): | 5 % ... 95 % (For UL applications max. 80 %) |
Pollution Degree: | 3 acc. to EN 60664-1, VDE 0110-1 |
Potted: | |
Product Family: | I/O Systems: Active - Standalone |
Product Sub Family: | LioN-Xlight |
Protection Class: | III, IEC 61140, EN 61140, VDE 0140-1 |
Protection Degree / IP Rating**: | IP65, IP67, IP69K |
Protection Degree / IP Rating Note: | *only if mounted and locked in combination with Hirschmann / Lumberg Automation connector. |
Protective Circuit: | Electronicaly: Overload protection, short-circuit protection |
Protective Circuit (#1): | Electronicaly: Overload protection, short-circuit protection |
Protocol (EtherNet/IP): | EtherNet/IP |
Quick Connect (QC): | Supported, ≤ 500 ms |
REST API: | Cyclic data read/write, Diagnosis data, Event data |
Reverse Polarity Protection: | |
Reverse Polarity Protection (#1): | |
RoHS Compliant: | |
Sensor Current Supply: | max. 4A per port via Pin1L+ |
Sensor Supply Voltage (Nominal): | 24 V DC (SELV/PELV) |
Sensor Supply Voltage (Range): | 20V DC to 30 V DC |
Sensor Type: | PNP |
Shock Resistance: | 50 g / 11ms |
Specification (#1): | CIP V3.2x, EIP Adaption of CIP V1.2x |
Status Indicator (IOL): | LED green per channel |
Status Indicator (Inputs): | LED white or yellow per channel |
Status Indicator (Outputs): | LED white or yellow per channel |
Status Indicator (Sensor Supply): | LED green |
Status Indicator (System Supply): | LED green |
Supported COM Modes: | 4.8 kBaud (COM 1), 38.4 kBaud (COM 2), 230.4 kBaud (COM 3) |
Supported Network Protocols (Other) (#1): | ACD, ARP, BootP, DHCP, HTTP, IGMP, Ping, TCP/IP |
Syslog: | |
System Power Supply Connection Note: | *do not connect / disconnect under voltage! |
Transmission Method: | 100 BASE-TX, with auto negotiation and auto crossing |
Transmission Rate (#3): | Fast Ethernet (10/100 Mbit/s), Full Duplex |
UL: | cULus Listed, UL 61010-1 |
UL / FE: | 500 V DC |
US (System Supply Voltage) / FE: | 500 V DC |
US / UL (Actuator Supply Voltage): | 500 V DC |
Uaux / FE: | 500 V DC |
Vibration Resistance: | 15 g / 5 -500 Hz |
Weight: | 500 g |
Width: | 60 mm |
Width (#1): | 2.3622 in |
uniek_nr: | 935701002 |