Product information
The AS-Interface Data Double-Ended Cordset features male straight A-coded orange M12 Standard to female straight A-coded orange M12 Standard connectors. It operates at 50 V AC / 60 V DC with a current rating of 4 A. The cordset includes a TPU orange cable with 4 wires and a conductor size of 0.50 mm². Designed to handle harsh environments, it offers reliable connection with high protection degrees of IP65, IP67, IP68, and IP69K. The materials used, such as CuSn for the contact base and TPU for the molded body, enhance durability and provide good resistance to chemicals and oils. The orange color ensures visibility, and the cable is rated for temperatures ranging from -40 °C to +90 °C, ensuring versatility in various industrial applications.
Downloads
Specifications
Pin Color 04@Side 2: | black |
---|---|
Operating Voltage: | 50 V AC / 60 V DC |
Oil Resistance: | Good chemical and oil resistance |
Number of Wires: | 4 |
Number of Pins, Side 2: | 4 |
Number of Pins: | 4 |
Overvoltage Category: | III acc. to DIN EN 60664-1 (VDE 0110-1) |
Overvoltage Category, Side 2: | III acc. to DIN EN 60664-1 (VDE 0110-1) |
Pin Color 04@Side 1: | black |
Pin Color 03@Side 2: | blue |
Pin Color 03@Side 1: | blue |
Pin Color 02@Side 2: | white |
Pin Color 02@Side 1: | white |
Pin Color 01@Side 2: | brown |
Pin Color 01@Side 1: | brown |
Part Number (#1): | 29717 |
Type of Contact / Gender, Side 2: | female |
Type of Contact / Gender: | Male |
Shielding: | Unshielded |
RoHS Compliant: | yes |
Rated Voltage: | 60 V |
UL Cable Type: | AWM: 20549 |
Wire Insulation Material: | PP |
Rated Impulse Voltage: | 1.5 kV |
Rated Current*: | 4 A |
Pollution Degree, Side 2: | 3 acc. to DIN EN 60664-1 (VDE 0110-1) |
Pollution Degree: | 3 acc. to DIN EN 60664-1 (VDE 0110-1) |
Product Family: | Data Connectors |
Product Sub Family: | M12 Standard |
Protection Degree / IP Rating, Side 2**: | IP65, IP67, IP68 (1 m / 24 h), IP69K |
Protection Degree / IP Rating**: | IP65, IP67, IP68 (1 m / 24 h), IP69K |
Protection Degree / IP Rating Note: | ** only if mounted and locked in combination with Hirschmann / Lumberg Automation connector. |
Product Sub Family, Side 2: | M12 Standard |
Note Derating: | Notice derating |
Connector Type: | Cordset, double ended |
Connector Design, Side 2: | Straight |
Connector Design: | Straight |
Conductor material: | Cu |
Conductor Size: | 0.5 mm² |
Coding, Side 2: | A |
Coding: | A |
Contact Base Material (#1): | CuSn |
Contact Base Material, Side 2: | CuSn |
Contact Resistance, Side 2: | ≤ 10 mOhm |
Contact Resistance: | ≤ 10 mOhm |
Contact Plating, Side 2: | Cu/Au |
Contact Plating: | Cu/Au |
Contact Bearer Material, Side 2: | TPU |
Contact Bearer Material (#1): | TPU |
Contact Bearer Color, Side 2: | Black |
Contact Bearer Color: | Orange |
Attachment Material, Side 2: | CuZn |
Attachment Material: | CuZn |
Ambient Temperature (Operation), Side 2*: | - 40 °C - + 90 °C |
Ambient Temperature (Operation)*: | - 40 °C - + 90 °C |
Ambient Temperature (Flex Installation): | - 5 °C - + 90 °C (UL: + 80 °C) |
Ambient Temperature (Fixed Installation): | - 40 °C - + 90 °C (UL: + 80 °C) |
Ambient Temperature (Drag Chain Inst): | max. + 60 °C |
Attachment Plating: | Nickel-plated |
Attachment Plating, Side 2: | Nickel-plated |
Attachment Type: | Coupling Screw |
Cable Number: | 034 |
Cable Length: | 3 m |
Cable Jacket Material: | TPU |
Cable Jacket Color: | orange matt similarly RAL 2003 |
Cable Diameter D: | ø 5.5 ± 0.2 mm |
Cable Characteristics: | Mainly plasticizer diffusion free; Exclusion of PVC and silicone; Good microbes and hydrolysis resistance; Coldness flexibility |
Attachment Type, Side 2: | Coupling Nut |
Note: | Do not connect or disconnect under load. |
Insulation Resistance: | ˃ 10^9 Ohm |
Insulated Wire Diameter: | ø 1.65 mm |
Halogenfree: | DIN VDE 0482 Teil 267, EN 50267-2-1, IEC 60754-1 |
Insulation Resistance Cable: | min 1000 MOhm x km |
Insulation Resistance, Side 2: | ˃ 10^9 Ohm |
Item Description: | 0915 034 101/3 M |
Molded Body Material, Side 2: | TPU |
Molded Body Material: | TPU |
Molded Body Color, Side 2: | orange |
Molded Body Color: | orange |
Minimal Bending Radius (Flexible Inst): | ˃ 10 x D |
Minimal Bending Radius (Fixed Inst): | ˃ 5 x D |
Mating Cycles, Side 2: | ≤ 100 |
Mating Cycles: | ≤ 100 |
Long Description (#1): | AS-Interface Data Double-Ended Cordset: Male straight A-coded orange M12 Standard to female straight A-coded orange M12 Standard, 50 V AC / 60 V DC, 4 A; TPU orange cable, 4-wires, 0.50 mm² |
Flammability Class (Molded Body), Side 2: | UL 94 HB |
Fastening Torque (Attachment): | M 12x1: (50-60) Ncm, hand-tight |
Design Standard, Side 2: | IEC 61076-2-101 |
Design Standard: | IEC 61076-2-101 |
Data Transmission: | AS-Interface |
Cycles (Bending): | ˃ 2 M |
Core Colors: | brown, white, blue, black |
Fastening Torque (Attachment), Side 2: | M 12x1: (50-60) Ncm, hand-tight |
Flammability Class (Molded Body): | UL 94 HB |
Flammability Class (Contact Bearer), Side 2: | UL 94 HB |
Flammability Class (Contact Bearer): | UL 94 HB |
Flammability Class (Cable Jacket): | IEC 60332-1 , VDE 0482-265-2-1 , EN 50265-2-1 , UL-FT2 |
Unique No.: | aut29717 |