Product information
The PROFIBUS Data Double-Ended Cordset is designed for reliable and efficient data transmission. It features a male angled B-coded black M12 connector on one end and a female angled B-coded black M12 connector on the other. The cordset is shielded for enhanced performance and stability, supporting 50 V AC / 60 V DC and 4 A of current. The PUR violet cable is robust and resilient, with a 0.34 mm² conductor size and 2-wires construction, ensuring durability in various industrial environments. With an impressive IP69K protection rating, it is suitable for use in harsh conditions, providing protection against dust and water ingress. This cordset is ideal for PROFIBUS applications, ensuring consistent and reliable data communication.
Downloads
Specifications
Pin Color 05@Side 2: | n.c. |
---|---|
Pin Color 05@Side 1: | n.c. |
Pin Color 04@Side 2: | red |
Operating Voltage: | 50 V AC / 60 V DC |
Operating Temperature (UL), Side 2: | max. + 50 °C |
Operating Temperature (UL): | max. + 50 °C |
Number of Wires: | 2 |
Number of Pins, Side 2: | 5 |
Number of Pins: | 5 |
Overall Shield (Cable): | Cu-ETP1 tinned |
Overvoltage Category: | III acc. to DIN EN 60664-1 (VDE 0110-1) |
Overvoltage Category, Side 2: | III acc. to DIN EN 60664-1 (VDE 0110-1) |
Pin Color 04@Side 1: | red |
Pin Color 03@Side 2: | n.c. |
Pin Color 03@Side 1: | n.c. |
Pin Color 02@Side 2: | green |
Pin Color 02@Side 1: | green |
Pin Color 01@Side 2: | n.c. |
Pin Color 01@Side 1: | n.c. |
Part Number (#1): | 934727006 |
Type of Contact / Gender, Side 2: | female |
Type of Contact / Gender: | Male |
Shielding Material, Side 2: | Housing: GD-Zn, nickel-plated; Sleeve: CuZn, tin-plated |
Shielding Material: | Housing: GD-Zn, nickel-plated; Sleeve: CuZn, tin-plated |
Shielding: | Shielded |
RoHS Compliant: | yes |
Rated Voltage (UL): | 30 V AC/DC |
Rated Voltage: | 60 V |
UL: | UL 2238; cURus |
UL Cable Type: | AWM: 20549 |
Wire Insulation Material: | PE |
UL-File: | E315587 |
Rated Impulse Voltage: | 1.5 kV |
Rated Current*: | 4 A |
Pollution Degree, Side 2: | 3 acc. to DIN EN 60664-1 (VDE 0110-1) |
Pollution Degree: | 3 acc. to DIN EN 60664-1 (VDE 0110-1) |
Product Family: | Data Connectors |
Product Sub Family: | M12 Standard |
Rated Current (UL)*: | 2.5 A |
Protection Degree / IP Rating, Side 2**: | IP65, IP67, IP68 (1 m / 24 h), IP69K |
Protection Degree / IP Rating**: | IP65, IP67, IP68 (1 m / 24 h), IP69K |
Protection Degree / IP Rating Note: | ** only if mounted and locked in combination with Hirschmann / Lumberg Automation connector. |
Product Sub Family, Side 2: | M12 Standard |
Note Derating: | Notice derating |
Connector Type: | Cordset, double ended |
Connector Design, Side 2: | angled |
Connector Design: | angled |
Conductor material: | Cu |
Conductor Size: | 0.34 mm² |
Coding, Side 2: | B |
Coding: | B |
Contact Base Material (#1): | CuZn |
Contact Base Material, Side 2: | CuZn |
Contact Resistance, Side 2: | ≤ 10 mOhm |
Contact Resistance: | ≤ 10 mOhm |
Contact Plating, Side 2: | Cu/Au |
Contact Plating: | Cu/Au |
Contact Bearer Material, Side 2: | PBT |
Contact Bearer Material (#1): | PBT |
Contact Bearer Color, Side 2: | Violett |
Contact Bearer Color: | Violett |
Attachment Material, Side 2: | CuZn |
Attachment Material: | CuZn |
Ambient Temperature (Operation), Side 2*: | - 40 °C - + 80 °C |
Ambient Temperature (Operation)*: | - 40 °C - + 80 °C |
Ambient Temperature (Flex Installation): | - 25 °C - + 80 °C |
Ambient Temperature (Fixed Installation): | - 50 °C - + 80 °C |
Ambient Temperature (Drag Chain Inst): | - 25 °C - + 60 °C |
Attachment Plating: | Nickel-plated |
Attachment Plating, Side 2: | Nickel-plated |
Attachment Type: | Coupling Screw |
Cable Number: | 254 |
Cable Length: | 3 m |
Cable Jacket Material: | PUR |
Cable Jacket Color: | violet matt similarly RAL 4001 |
Cable Diameter D: | ø 7.60 ± 0.30 mm |
Cable Characteristics: | Exclusion of dangerous materials; Line fulfills the transmission values RS485 (Type A) of the PROFIBUS user organization; Free of lacquer wetting disturbing substances; Good microbes and hydrolysis resistance Mainly plasticizer diffusion free; Good chemic |
Attachment Type, Side 2: | Coupling Nut |
Note: | Do not connect or disconnect under load. |
Insulation Resistance: | ˃ 10^9 Ohm |
Insulated Wire Diameter: | ø 2.60 ± 0.05 mm |
Halogenfree: | DIN EN 50267-2-1, IEC 60754-1, VDE 0482-267-2-1 |
Insulation Resistance Cable: | ˃ 2500 MΩxkm |
Insulation Resistance, Side 2: | ˃ 10^9 Ohm |
Item Description: | 0975 254 130/3 M |
Molded Body Material, Side 2: | TPU |
Molded Body Material: | TPU |
Molded Body Color, Side 2: | Black |
Molded Body Color: | Black |
Minimal Bending Radius (Flexible Inst): | ˃ 10 x D |
Minimal Bending Radius (Fixed Inst): | ˃ 5 x D |
Mating Cycles, Side 2: | ≤ 100 |
Mating Cycles: | ≤ 100 |
Long Description (#1): | PROFIBUS Data Double-Ended Cordset: Male angled B-coded black M12 Standard to female angled B-coded black M12 Standard, shielded, 50 V AC / 60 V DC, 4 A; PUR violet cable, 2-wires, 0.34 mm² |
Foil shield: | Al-PT Foil |
Flammability Class (Molded Body), Side 2: | UL 94 V-2 |
Fastening Torque (Attachment): | M 12x1: (50-60) Ncm, hand-tight |
Design Standard, Side 2: | IEC 61076-2-101 |
Design Standard: | IEC 61076-2-101 |
Data Transmission: | PROFIBUS |
Cycles (Bending): | ˃ 1 M |
Core Colors: | red, green |
Fastening Torque (Attachment), Side 2: | M 12x1: (50-60) Ncm, hand-tight |
Flammability Class (Molded Body): | UL 94 V-2 |
Flammability Class (Contact Bearer), Side 2: | UL 94 HB |
Flammability Class (Contact Bearer): | UL 94 HB |
Flammability Class (Cable Jacket): | DIN EN 60332-2-2, VDE 0482-332-2-2, IEC 60332-2-2, CSA FT-2, flame-retardant |
Unique No.: | aut934727006 |