The PROFIBUS Data Single-Ended Cordset is designed to provide reliable data connections in industrial environments. It features an M12 standard female connector, straight design with 5 pins and B-coding, and a shielded black body. Operating at 50 V AC / 60 V DC with a rated current of 4 A, it ensures high-performance data transmission. The PUR violet cable has two wires with a cross-section of 0.34 mm², offering excellent resistance to chemicals, oil, and microbes, as well as flexibility in cold conditions. The cordset is suitable for use in demanding applications where reliable data communication is critical.
Downloads
Specifications
Ambient Temperature (Drag Chain Inst): | - 25 °C - + 60 °C |
---|---|
Ambient Temperature (Fixed Installation): | - 50 °C - + 80 °C |
Ambient Temperature (Flex Installation): | - 25 °C - + 80 °C |
Ambient Temperature (Operation)*: | - 25 °C - + 80 °C |
Attachment Material: | CuZn |
Attachment Plating: | Nickel-plated |
Attachment Type: | Coupling Nut |
Cable Characteristics: | Exclusion of dangerous materials; Line fulfills the transmission values RS485 (Type A) of the PROFIBUS user organization; Free of lacquer wetting disturbing substances; Good microbes and hydrolysis resistance Mainly plasticizer diffusion free; Good |
Cable Diameter D: | ø 7.60 ± 0.30 mm |
Cable Jacket Color: | violet matt similarly RAL 4001 |
Cable Jacket Material: | PUR |
Cable Length: | 50 m |
Cable Number: | 254 |
Coding: | B |
Conductor Size: | 0.34 mm² |
Conductor material: | Cu |
Connector Design: | Straight |
Connector Type: | Cordset, single ended |
Contact Base Material (#1): | CuZn |
Contact Bearer Color: | Violett |
Contact Bearer Material (#1): | TPU |
Contact Plating: | Cu/Au |
Contact Resistance: | ≤ 10 mOhm |
Core Colors: | red, green |
Cycles (Bending): | ˃ 1 M |
Data Transmission: | PROFIBUS |
Design Standard: | IEC 61076-2-101 |
Fastening Torque (Attachment): | M 12x1: (50-60) Ncm, hand-tight |
Flammability Class (Cable Jacket): | DIN EN 60332-2-2, VDE 0482-332-2-2, IEC 60332-2-2, CSA FT-2, flame-retardant |
Flammability Class (Contact Bearer): | UL 94 HB |
Flammability Class (Molded Body): | UL 94 HB |
Foil shield: | Al-PT Foil |
Halogenfree: | DIN EN 50267-2-1, IEC 60754-1, VDE 0482-267-2-1 |
Insulated Wire Diameter: | ø 2.60 ± 0.05 mm |
Insulation Resistance: | ˃ 10^9 Ohm |
Insulation Resistance Cable: | ˃ 2500 MΩxkm |
Item Description: | 0975 254 103/50 M |
Long Description (#1): | PROFIBUS Data Single-Ended Cordset: M12 Standard, female, straight, 5-pin, B-coded, shielded, black body, 50 V AC / 60 V DC, 4 A; PUR violet cable, 2-wires, 0.34 mm² |
Mating Cycles: | ≤ 100 |
Minimal Bending Radius (Fixed Inst): | ˃ 5 x D |
Minimal Bending Radius (Flexible Inst): | ˃ 10 x D |
Molded Body Color: | Black |
Molded Body Material: | TPU |
Note: | Do not connect or disconnect under load. |
Note Derating: | Notice derating |
Number of Pins: | 5 |
Number of Wires: | 2 |
Operating Voltage: | 50 V AC / 60 V DC |
Overall Shield (Cable): | Cu-ETP1 tinned |
Overvoltage Category: | III acc. to DIN EN 60664-1 (VDE 0110-1) |
Part Number (#1): | 7072 |
Pin Color 01@Side 1: | n.c. |
Pin Color 02@Side 1: | green |
Pin Color 03@Side 1: | n.c. |
Pin Color 04@Side 1: | red |
Pin Color 05@Side 1: | n.c. |
Pollution Degree: | 3 acc. to DIN EN 60664-1 (VDE 0110-1) |
Product Family: | Data Connectors |
Product Sub Family: | M12 Standard |
Protection Degree / IP Rating**: | IP65, IP67 |
Protection Degree / IP Rating Note: | ** only if mounted and locked in combination with Hirschmann / Lumberg Automation connector. |
Rated Current*: | 4 A |
Rated Impulse Voltage: | 1.5 kV |
Rated Voltage: | 60 V |
RoHS Compliant: | yes |
Shielding: | Shielded |
Shielding Material: | CuZn, tin-plated |
Type of Contact / Gender: | Female |
UL Cable Type: | AWM: 20549 |
Wire Insulation Material: | PE |
uniek_nr: | aut7072 |